BTU Calculator

BTU/h = the ENERGY STAR chart value for the room's area: a 15 × 20 ft room (300 ft²) needs 8,000 BTU/h. Add 10 % for a very sunny room, 600 BTU/h per person above two and 4,000 BTU/h for a kitchen.

Units

Cooling capacity needed

8,000 BTU/h

2.34 kW · 0.67 tons

Room area
300 ft²
ENERGY STAR chart base
8,000 BTU/h

Chart values assume 8 ft ceilings. For higher ceilings or poor insulation, choose the next size up or ask an HVAC pro.

How it works

Area = length × width

Base capacity = ENERGY STAR chart value for that area (e.g. 450–550 ft² → 12,000 BTU/h)

Heavily shaded: −10 % · very sunny: +10 %

+600 BTU/h for each regular occupant above two · kitchen: +4,000 BTU/h

Assumptions

Worked examples

A 450 ft² living room, very sunny, 4 people

  1. Chart: 450 ft² falls in 450–550 → 12,000 BTU/h
  2. Very sunny: 12,000 × 1.10 = 13,200
  3. Two people above two: + 2 × 600 = 14,400 BTU/h

Result: 14,400 BTU/h.

Checked by the automated test “BTU — 450 ft², very sunny, 4 people = 14,400 BTU/h”.

A 12 × 15 ft kitchen

  1. 12 × 15 = 180 ft² → 6,000 BTU/h
  2. Kitchen: + 4,000 = 10,000 BTU/h

Result: 10,000 BTU/h.

Checked by the automated test “BTU — 180 ft² kitchen = 10,000 BTU/h”.

Picking a unit size

Common mistakes

Frequently asked questions

How many BTU per square foot do I need?

There is no fixed rate in the ENERGY STAR method: it uses a chart. A 300 ft² room gets 8,000 BTU/h (about 27 per ft²), a 1,000 ft² room 21,000 BTU/h (21 per ft²). Sun, people and a kitchen then change the figure.

How many tons of air conditioning do I need?

Divide the BTU/h by 12,000, the size of one ton of cooling (NIST). The 14,400 BTU/h room above needs 1.2 tons. For a whole house, ENERGY STAR says the contractor should calculate your home's heating and cooling loads with ACCA Manual J or an equivalent method.

What room size does a 10,000 BTU air conditioner cool?

Read the ENERGY STAR chart backwards: 8,000 BTU/h is listed for 300 to 350 ft², 10,000 BTU/h for 400 to 450 ft² and 12,000 BTU/h for 450 to 550 ft², before any adjustment for sun, people or a kitchen. Bigger is not better: ENERGY STAR warns that a unit that is too large cools the room before it has a chance to remove the humidity, so the room feels damp and clammy.

Can I use this for heating?

No. The ENERGY STAR chart sizes room air conditioners for cooling. To size a heating system, ENERGY STAR asks the contractor to calculate your home's heating load with ACCA Manual J or an equivalent method.

Sources

Formula, examples and sources checked on by the Yardstick Math team. How we check our formulas.

  1. Room Air Conditioners – how to choose the right size (cooling capacity chart and adjustments) — ENERGY STAR (US EPA)
  2. Room Air Conditioner fact sheet — ENERGY STAR (US EPA)
  3. Heating & Air Conditioning Installation Bid Comparison Checklist (load calculation with ACCA Manual J or equivalent) — ENERGY STAR (US EPA and US DOE)
  4. NIST Guide to the SI, Appendix B.8 – Factors for units listed alphabetically (ton of refrigeration = 12,000 BTU/h) — NIST